Stealth Pro

The QuietCool Stealth Pro Series line is only available through installers. Outfitted with an ECM, Energy Saving Motor, they provide amazing energy saving as well as huge cost reduction on energy consumption. The Stealth Pro is one powerful fan, providing coverage of 1,478-6,996 cubic feet per minute for rooms/homes ranging from 439-3498 SQFT. Below you will find various QuietCool Stealth Pro models. Give us a call if you have any further questions!

Benefits

A QuietCool Stealth Pro can provide various benefits to your home and health. These benefits have been proven and the fan works effectively when installed properly. Our technicians are fast, reliable, and friendly and can get any QuietCool whole house fan installation done right. Check out these benefits a QuietCool whole house fan can offer.

  • QuietCool Lowers A/C Run Time by up to 90%
  • Safely Remove Pet Dander and Odors
  • Remove Cooling Odors and Heat
  • Remove Bathroom Odors, Steam, and Humidity
  • Expels Odors, Germs, Smoke, and VOC Gases
  • Say Goodbye to Hot, Sleepless Nights
  • Helps Prevent Mold and Mildew
  • Remove Unsightly Box Fans and Air Blower

Whole House Fans

Whole house fans are the most cost efficient way to cool a home. These fans work by pulling the outdoor air in through a home and out through the attic space. These fans work perfectly during the hot summer months and can be set to run all day or all night depending on the weather.

We provide professional installation services as well as walk you through on how to properly use these systems. Let us know if you would like a free quote over the phone, we would love to help!

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: 66.7 Watts

– Air Flow: 1479 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 740 SQFT

– Number of Speeds: 1

– Duct Diameter: 14″

– Duct Length: 6ft.

– Motor Head Diameter: 14 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 1.98 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 14 1/4″

– Removable Grille Outside Dimension: 16″ x 16″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 157 Watts / Low: 82.3 Watts

– Air Flow: Hi: 2541 CFM / Low: 2018 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1280 SQFT

– Number of Speeds: 2

– Duct Diameter: 16″

– Duct Length: 6ft.

– Motor Head Diameter: 16 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 3.39 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 18 1/4″

– Removable Grille Outside Dimension: 16″ x 20″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 264 Watts / Low: 74.6 Watts

– Air Flow: Hi: 3159 CFM / Low: 1980 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1580 SQFT

– Number of Speeds: 2

– Duct Diameter: 16″

– Duct Length: 6ft.

– Motor Head Diameter: 16 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 4.22 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 22 1/4″

– Removable Grille Outside Dimension: 16″ x 24″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 408 Watts / Med: 225 Watts / Low: 73.9 Watts

– Air Flow: Hi: 4280 CFM / Med: 3500 CFM / Low: 2361 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2140 SQFT

– Number of Speeds: 3

– Duct Diameter: 18″

– Duct Length: 9ft.

– Motor Head Diameter: 18 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and Double 3-Way

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 5.71 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 30 1/4″

– Removable Grille Outside Dimension: 16″ x 32″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 490 Watts / Med: 268 Watts / Low: 88 Watts

– Air Flow: Hi: 5044 CFM / Med: 4238 CFM / Low: 2870 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2530 SQFT

– Number of Speeds: 3

– Duct Diameter: 20″

– Duct Length: 9ft.

– Motor Head Diameter: 20 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and Double 3-Way

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 6.73 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 30 1/4″

– Removable Grille Outside Dimension: 16″ x 32″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 462 Watts / Med: 210 Watts / Low: 113 Watts

– Air Flow: Hi: 5587 CFM / Med: 4262 CFM / Low: 3428 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2800 SQFT

– Number of Speeds: 3

– Duct Diameter: 22″

– Duct Length: 9ft.

– Motor Head Diameter: 22 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and Double 3-Way

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 7.45 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 36 1/4″

– Removable Grille Outside Dimension: 16″ x 38″

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 725 Watts / Med: 319 Watts / Low: 166 Watts

– Air Flow: Hi: 6996 CFM / Med: 5448 CFM / Low: 4308 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 3500 SQFT

– Number of Speeds: 3

– Duct Diameter: 24″

– Duct Length: 9ft.

– Motor Head Diameter: 24 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and Double 3-Way

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 9.33 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 36 1/4″

– Removable Grille Outside Dimension: 16″ x 38″

Removable Grille

Each QuietCool Trident Pro whole house fan model includes a removable egg‐crate grille. Not only is this grille extremely stylish, but since it is removable, it is very easy to clean. Better yet, with our simple removable design, it is easy to add our R40 Winterized Kit option to seal your QuietCool with R45 value during the cold months of the year.

quietcool-damper-box

R5 Insulated Damper System

The included damper system features barometric pressurized gravity dampers that ensure there will be no heat/cooling loss between the home and attic. Compare this to traditional whole house fans that have old‐style shutters with zero R‐Value.

quietcool-trident-pro-two-way-switch

Included Wall Switch Control

All Stealth Pro models include the needed wall‐switch controls standard. This includes an Electronic 8‐Hour Countdown Timer and a speed control switch (when applicable).

quietcool-trident-pro-rf-switch

RF Control

This is a new dealer exclusive QuietCool switch. This is capable of controlling your fan anywhere from your home. It can be mounted on the wall or you can carry it with you.

There’s a slight difference between the two when it comes to CFM, Cubic Feet Per Minute, but there is a major difference in the motor. The Stealth Pro has an Electronically Commutated Motor (ECM) and the Trident Pro has a Permanent Split Capacitor Motor (PSC).

It’s good to run the whole house fan while the air conditioning unit is in use. This will exhaust all the built-up cool air in the home that is produced by the air conditioning unit.

Unless you want to heat up your home it is strongly advised not to use the whole house fan while it’s hot outside.

Looking for a quality and affordable electrician for your next project?